Answers
Is there a PSI limit for pressure washing travertine?
No stone body publishes a PSI for travertine. NSI's design manual names a method instead: fiber brushes, mild soap or detergent, and clean water.
Read it
Free estimates
Call 239-500-WASH Free estimate Ask a questionNaples, Marco Island, Estero and Bonita Springs, FL
Answers
Anyone with a brick walkway beside a concrete paver driveway wonders whether one cleaning suits both, and a method that is routine on concrete can go well past what the brick association allows on clay.
Short answer
No. In Florida a unit sold as a brick paver can be concrete, so the first step is finding out which material is laid. Fired clay follows the Brick Industry Association's Technical Note 20: the gentlest effective method, 400 psi at the nozzle unless the brick maker permits more, and no unbuffered muriatic or hydrofluoric acid. Concrete pavers follow ICPI Tech Spec 5.
The name
Start with a Florida paver maker. Tremron sells “brick pavers,” and it specifies its pavers to ASTM C936, the standard specification for interlocking concrete paving units. The word brick in a product name does not tell you the unit is fired clay.
That matters because the material, not the trade name, decides which cleaning rulebook applies. Fired clay has one, written by the Brick Industry Association. Concrete has another, written by the Interlocking Concrete Pavement Institute. The installer or the supplier who provided the units is the reliable source for which one was laid.
The edge of the unit will not settle it either. BIA says clay pavers can have edges that are square, round, beveled or relieved, and ICPI's glossary defines a chamfer on concrete units as a 45 degree beveled edge, so a beveled edge turns up in both documents.
Fired clay
The Brick Industry Association's Technical Note 20, “Cleaning Brickwork,” dated August 2018, states its reach in its abstract: “This Technical Note addresses cleaning of brickwork and brick pavements.” It covers clay brick paving, not concrete pavers.
Its governing instruction is a method, not a machine: “Select the gentlest effective cleaning method.” Its other paving-relevant limits sit beside that line.
The number in those limits is a clay brick number, measured at the nozzle tip, and it means nothing for another material without that material's own document; what the unit measures is under PSI, pounds per square inch.
Concrete
ICPI Tech Spec 5 describes professional cleaning of interlocking concrete pavers with a high pressure sprayer applying cleaner and water between 1,000 and 4,000 psi. That range is written for concrete pavers, and ICPI pairs it with a nozzle and an angle chosen to keep the joint sand where it is.
ICPI's reasoning is about the joints: “A nozzle that creates a wide spray enables a large area to be covered efficiently and prevents sand from being washed from the joints.” Its cleaners are typically a mix of detergent and acid, and it warns that “Cleaners with strong acids will change the color of the pavers slightly,” which is why a small test area comes first on concrete too.
A concrete paver maker adds its own line for its own product. Tremron, on its own concrete pavers, says muriatic acid will damage the surface of the pavers and cause pitting. Each line belongs to its owner. The limits for concrete pavers, travertine and clay brick sit side by side in one table under cleaning limits by paver material.
Side by side
Put the two documents next to each other and pressure washing clay brick the way concrete pavers are washed runs into BIA's limits on every line that matters.
Clay brick pavers and concrete pavers, each by its own document
| Point | Fired clay (BIA Technical Note 20) | Concrete pavers (ICPI Tech Spec 5) |
|---|---|---|
| Pressure | 400 psi maximum at the nozzle tip unless the brick maker permits more; above 800 psi is not appropriate for brick | Cleaner and water between 1,000 and 4,000 psi, wide spray nozzle, low angle |
| Acid | No unbuffered muriatic or hydrofluoric acid | Cleaners are typically detergent and acid; strong acids change color slightly |
| Approval and trial | Method and solution matched to the brick and approved by the brick manufacturer; a trial on a 20 square foot sample area | Cleaners tried on a small area to test results and any color changes |
| Joints | Acid-based solutions may not suit pavements with joint sand stabilizers or polymeric sand | Wide spray and low angle keep joint sand in the joints |
Each figure belongs to the material and the document in its column and does not transfer to the other.
The joints row deserves a second look. BIA notes that “acid-based cleaning solutions may not be appropriate for pavements containing joint sand stabilizers or polymeric sand,” and recommends verifying the compatibility of the cleaner with the paver manufacturer before selecting a solution for brick pavements. A brick pavement with joint stabilization puts two approvals in play, not one. What buffering an acid changes is explained under buffered acid and paver cleaners.
Approvals
Three decisions sit with people other than the cleaner: which material the unit is, an answer for the installer or supplier; whether the brick maker approves the method and the solution, under BIA's note; and whether the cleaner suits stabilized or polymeric sand joints, which BIA sends to the paver manufacturer.
That chain assumes a brick maker still exists to ask. Reclaimed brick from a brickyard that has closed breaks it, a case set out under reclaimed Chicago brick and the missing maker. Whether clay brick should be coated after cleaning is a separate question, answered under whether brick pavers can be sealed.
Technical Note 20 defines high pressure as greater than 800 psi and says high-pressure water cleaning is not appropriate for brick and may damage the brickwork. Its working limit sits well below that: do not use water pressures higher than 400 psi as measured at the nozzle tip unless the brick manufacturer permits more.
The installer or the supplier who provided the units. The product name is not enough: Tremron, a Florida paver maker, sells brick pavers and specifies its pavers to ASTM C936, the standard specification for interlocking concrete paving units. The material, not the name, decides whether BIA's or ICPI's cleaning document applies.
BIA Technical Note 20 calls for a trial cleaning on a 20 square foot sample area, using a method and solution matched to the type of brick and approved by the brick manufacturer. ICPI Tech Spec 5 asks for a small test area on concrete pavers too, to check results and any color change before a cleaner goes on the whole surface.
Sources
Every technical statement above is drawn from one of these documents. Nothing on this page about 239 Exteriors goes beyond what the company itself states.
Page reviewed September 14, 2026. Florida statutes are quoted from the 2026 Florida Statutes; every image on this page is a labeled concept illustration, not a photograph of a completed job.
Keep reading
Answers
No stone body publishes a PSI for travertine. NSI's design manual names a method instead: fiber brushes, mild soap or detergent, and clean water.
Read itGlossary
What Chicago brick is: fired common brick from Chicago's blue clay, once the brick of side and rear walls, sold today as reclaimed brick with no working brickyard.
Read itGlossary
ICPI's definition of a mortar-set pavement, why BIA says it belongs only over a concrete base, and the Type R clay pavers built for that rigid system.
Read itRestore. Protect. Impress.
Deep cleaning for driveways, patios and walkways, then a protective sealant against stains, UV damage and weeds.
Read itFree estimate
Call 239-500-WASH, or send the form and 239 Exteriors will follow up.
Free estimate
Tell us which surface you are asking about and anything about the property that helps.
Request received
Your request is in. 239 Exteriors will follow up with a free estimate. Need to reach us sooner? Call 239-500-WASH.
The form did not send
Nothing was lost, but this request did not go through. Call 239-500-WASH and we will take the details by phone, or try the form again in a moment.
Request received
Your request is in. 239 Exteriors will follow up with a free estimate. Need to reach us sooner? Call 239-500-WASH.
The form did not send
Nothing was lost, but this request did not go through. Call 239-500-WASH and we will take the details by phone, or try the form again in a moment.